Error Codes Canon IR1730 IR1740 IR1750 - SERVICE MANUAL *.* FIRMWARE
Login




Error Codes Canon IR1730 IR1740 IR1750

Code Cause Remedy
E000 Fixing temperature rising error
0001 The detected temperature of the Main Thermistor failed to reach the specified temperature at temperature rising control. Go through the following to clear the error: CLEAR > ENGINE > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Check the connector connection. (J206 on the DC Controller PCB,J101 on the Power Supply PCB)
Replace the Fixing Assembly.
Replace the DC Controller PCB (PCB1).
E001 Detection of overheating of Fixing Assembly
0000 The Main Thermistor detected 250 deg C or higher for 200 msec or longer on end. Go through the following to clear the error: CLEAR > ENGINE > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Check the connector connection. (J206 on the DC Controller PCB,J101 on the Power Supply PCB)
Replace the Fixing Assembly.
Replace the DC Controller PCB (PCB1).
0001 The hardware circuit detected overheating of the Main Thermistor or Sub Thermistor for 30 msec or longer. Go through the following to clear the error: CLEAR > ENGINE > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Replace the DC Controller PCB (PCB1).
0002 The Sub Thermistor detected 295 deg C or higher for 200msec or longer on end. Go through the following to clear the error: CLEAR > ENGINE > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Check the connector connection. (J206 on the DC Controller PCB,J101 on the Power Supply PCB)
Replace the Fixing Assembly.
Replace the DC Controller PCB (PCB1).
E002 Error in temperature rising of Fixing Assembly
0000 The Main Thermistor detected a temperature lower than 115 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 100 deg C.
The Main Thermistor detected a temperature lower than 150 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 140 deg C.
Go through the following to clear the error: CLEAR > ENGINE > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Check the connector connection. (J206 on the DC Controller PCB,J101 on the Power Supply PCB)
Replace the Fixing Assembly.
Replace the DC Controller PCB (PCB1).
E003 Detection of fixing low temperature during printing
0000 The Main Thermistor detected a temperature lower than 80 deg C for 200 msec or longer on end, or the Sub Thermistor detected a temperature lower than 60 deg C for 200 msec or longer on end Go through the following to clear the error: CLEAR > ENGINE > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Check the connector connection. (J206 on the DC Controller PCB,J101 on the Power Supply PCB)
Replace the Fixing Assembly.
Replace the DC Controller PCB (PCB1).
E004 Thermistor disconnection detection error
0000 Connector disconnection was detected for 30 msec on end. Check the connector connection. (J206 on the DC Controller PCB,J101 on the Power Supply PCB)
Replace the Fixing Assembly.
Replace the DC Controller PCB (PCB1).
E010 Main Motor (M2) rotation error
0001 Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds. Check the connector between the Main Motor and the DC Controller PCB (J203).
Replace the Main Motor (M2).
Replace the DC Controller PCB (PCB1).
0002 Detection was performed every 100msec during the drive (after the lock detection) and the lock signal was not detected 5 times in a row (in 500 msec).
E013 Error in rotation of Waste Toner Motor (M3)
0000 Lock detection flag was monitored every 2msec, and the same level was detected 600 times in a row. Check the connector connection between the Waste Toner Motor and the DC Controller PCB (J209).
Replace the Waste Toner Motor (M3).
Replace the DC Controller PCB (PCB1).
E014 Fixing Motor (M1) rotation error
0001 Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds. Check the connector connection between the Fixing Motor and the DC Controller PCB (J203).
Replace the Fixing Motor (M1).
Replace the DC Controller PCB (PCB1)
0002 Detection was performed every 100 msec during the drive (after the lock detection) and the lock signal was not detected 5 times in a row (in 500 msec).
0003 Pressure release had never been detected in 3.0 seconds.
0004 Pressurization had never been detected in 3.0 seconds.
E020 Detection of toner clog between the Hopper and the Developing Assembly
0000 When the Developing Assembly Toner Sensor (TS2) detected "tonerabsent" and the Hopper Toner Sensor (TS1) detected "toner-present", the Hopper Motor (M6) was rotated 194 times with intermissions of 1 second, but the Developing Assembly Toner Sensor (TS2) could not detect "toner-present".
* If paper is being fed, the error occurs after the paper has been delivered.
Check rotation of the Hopper Motor Gear. (If it is rotating, the sensor may not be detecting correctly. In that case, execute Service Mode >CLEAR>ENGINE>TNRINST to supply toner to the Developing Assembly.)
Replace the Developing Assembly Toner Sensor (TS2).
Replace the Hopper Toner Sensor (TS1).
Replace the DC Controller PCB (PCB1).
E024 Connector disconnection of the Developing Assembly Toner Sensor (TS2) or the DC Controller PCB (J209)
0000 Developing Assembly Toner Sensor (TS2) connection detection signals were not detected 10 times in a row in 100 msec.
* If paper is being fed, the error occurs after the paper has been delivered
Check the connection of the Connector (J209).
Replace the Developing Assembly Toner Sensor (TS2).
Replace the DC Controller PCB (PCB1).
0001 At normal speed: Developing Assembly Toner Sensor (TS2) signals were detected 7500 times in a row at intervals of 100 msec.
At low speed: Developing Assembly Toner Sensor (TS2) signals were detected 4500 times in a row at intervals of 100 msec.
Check the connection of the Connector (J209).
Correct the wiring.
Replace the Developing Assembly Toner Sensor (TS2).
E025 Connector disconnection of the Hopper Toner Sensor (TS1) or the DC Controller PCB (J211) or Bottle Motor (M5) error
0000 Hopper Toner Sensor (TS1) connection detection signals were not detected 10 times in a row in 100 msec.
* If paper is being fed, the error occurs after the paper has been delivered.
Check the connection of the Connector (J211).
Replace the Hopper Toner Sensor (TS1).
Replace the DC Controller PCB (PCB1).
0001 The lock detection flag of the Bottle Motor (M5) was monitored at intervals of 2 msec, and the same level was detected 800 times in a row.
* If paper is being fed, the error occurs after the paper has been delivered.
Replace the Bottle Motor (M5).
Replace the DC Controller PCB (PCB1).
E110 Laser Scanner Motor error
0001 After startup of the Laser Scanner Motor, the speed lock signal of the Laser Scanner Motor never showed lock status although a specified period of time had passed.
*When the same status was detected again after executing an error retry.
Check the Laser Scanner Unit connector.
Replace the Laser Scanner Unit.
Replace the DC Controller PCB (PCB1).
0002 After the speed lock of the Laser Scanner Motor had been settled, intervals of 100 msec.
*When the same status was detected again after executing an error retry.
0003 The speed lock signal of the Laser Scanner Motor never showed lock status although 6.5 seconds (when switching from low speed to normal speed) or 8 seconds (when switching from normal speed to low speed) have passed.
*When the same status was detected again after executing an error retry.
E196 EEPROM access error
0000 During communication with EEPROM, a communication error occurred, and the error was not cleared although a retry was executed three times.
* If paper is being fed, the error occurs after the paper has been delivered.
Replace the DC Controller PCB (PCB1).
E197 Laser Driver PCB communication error
0000 Error in communication with the Laser Driver PCB (communication data failure) Check the Laser Scanner Unit connector.
Replace the Laser Scanner Unit.
Replace the DC Controller PCB (PCB1).
0001 Error in communication with the Laser Driver PCB (serial communication failure)
E202 CIS home position detection error
0000 Error when moving to the left side for HP check operation
Error when moving to the right side for HP check operation
Disconnect and then connect the Flexible Cable (Reader Controller PCB (PCB3) - Main Controller PCB (PCB2) 31pin).
Replace the Flexible Cable.
Replace the Reader Motor (M10).
Replace the Reader Controller PCB (PCB3).
Replace the Main Controller PCB (PCB2).
E240 Controller communication error
0000 A serial communication error was detected during normal operation. Check the connector connection. (All connectors on the DC Controller PCB, J8112 on the Main Controller PCB)
Replace the DC Controller PCB (PCB1).
0001 A serial communication error was detected during printing.
E246
E247
System error
XXXX Contact the service company office
E261 Zero cross signal error
0000 When the relay is ON, the zero cross signal failed to be detected for 500 msec or longer.
*When the same status was detected again after executing an error retry.
Check the connector connection. (All connectors on the DC Controller PCB)
Replace the DC Controller PCB (PCB1).
E350
E354
E355
System error
XXXX Contact the service company office
E530 Front Alignment Motor (M4) error
8001 At initialization of the Front Alignment Plate, the Front Alignment Plate failed to move from the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 10 mm. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
Replace the Front Alignment Plate HP Sensor (S4).
Replace the Front Alignment Motor (M4).
Replace the Finisher Controller PCB.
8002 At initialization of the Front Alignment Plate, the Front Alignment Plate failed to be detected by the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 0.78 seconds.
E531 Staple Motor (M9) error
8001 The Stapler failed to move from the Staple HP Sensor (S11) within the staple execution time (0.45sec). Check the connector connection of the Staple Unit.
Check for open circuit of the Harness of the Staple Unit.
Replace the Staple Unit.
Replace the Finisher Controller PCB.
8002 After execution of staple operation, the motor was operated in the positive direction, but the Staple Unit could not be detected by the Staple HP Sensor (S11) within 0.46 seconds. Then, the motor was rotated in the negative direction, but the Staple Unit could not be detected by the Staple HP Sensor (S11) within 0.46sec. Check the connector connection of the Staple Unit.
Disconnect the Harness of the Staple Unit.
Replace the Staple Unit.
Replace the Finisher Controller PCB
E537 Rear Alignment Motor (M5) error
8001 At initialization of the Rear Alignment Plate, the Rear Alignment Plate failed to move from the Rear Alignment Plate HP Sensor (S5) although the Rear Alignment Motor (M5) was driven for 10 mm. Check the connector connection of the Rear Alignment Plate HP Sensor (S5) or the Rear Alignment Motor (M5).
Check for open circuit of the Harness of the Rear Alignment Plate HP Sensor (S5) or the Rear Alignment Motor (M5).
Replace the Rear Alignment Plate HP Sensor (S5).
Replace the Rear Alignment Motor (M5).
Replace the Finisher Controller PCB.
8002 At initialization of the Rear Alignment Plate, the Rear Alignment Plate failed to be detected by the Rear Alignment Plate HP Sensor (S5) although the Rear Alignment Motor (M5) was driven for 0.78sec.
E540 Stack Tray Shift Motor (M8) error
8001 The Stack Tray Shift Motor (M8) was driven for 4 seconds, but the Stack Tray shifting operation could not be completed. Check the connector connection of the Stack Tray Paper Height Sensor (S9) or the Stack Tray Shift Motor (M8).
Check for open circuit of the Harness of the Stack Tray Paper Height Sensor (S9) or the Stack Tray Shift Motor (M8).
Replace the Stack Tray Paper Height Sensor (S9).
Replace the Stack Tray Shift Motor (M8).
Replace the Finisher Controller PCB.
E575 Gripper Motor (M7) error
8002 The gripper unit does not leave the gripper unit home position when the Gripper Motor (M7) has been driven for 3.8 seconds. Check the connector connection of the Gripper HP Sensor (S7) or the Gripper Motor (M7).
Check for open circuit of the Harness of the Gripper HP Sensor (S7) or the Gripper Motor (M7).
Replace the Gripper HP Sensor (S7).
Replace the Gripper Motor (M7).
Replace the Finisher Controller PCB.
8004 When the Gripper Motor (M7) was operated, the Gripper Encoder Sensor (S8) detected rotation of 400 clocks or more. Check the connector connection of the Gripper Encoder Sensor (S8) or the Gripper Motor (M7).
Check for open circuit of the Harness of the Gripper Encoder Sensor (S8) or the Gripper Motor (M7).
Replace the Gripper Encoder Sensor (S8).
Replace the Gripper Motor (M7).
Replace the Finisher Controller PCB.
E577 Paddle Motor (M3) error
8001 Although the Paddle Motor (M3) was driven for 175 steps, the Paddle failed to move from the Paddle HP Sensor (S3). Check the connector connection of the Paddle HP Sensor (S3) or the Paddle Motor (M3).
Check for open circuit of the Harness of the Paddle HP Sensor (S3) or the Paddle Motor (M3).
Replace the Paddle HP Sensor (S3).
Replace the Paddle Motor (M3).
Replace the Finisher Controller PCB.
8002 The Paddle Motor (M3) was driven for 2 seconds, but the Paddle could not be detected by the Paddle HP Sensor (S3).
E583 Tray Auxiliary Guide Motor (M6) error
8001 The Tray Auxiliary Guide Motor (M6) was driven for 30 mm, but the Tray Auxiliary Guide failed to move from the Tray Auxiliary Guide HP Sensor (S6). Check the connector connection of the Tray Auxiliary Guide HP Sensor (S6) or the Tray Auxiliary Guide Motor (M6).
Check for open circuit of the Harness of the Tray Auxiliary Guide HP Sensor (S6) or the Tray Auxiliary Guide Motor (M6).
Replace the Tray Auxiliary Guide HP Sensor (S6).
Replace the Tray Auxiliary Guide Motor (M6).
Replace the Finisher Controller PCB.
8002 The Tray Auxiliary Guide Motor (M6) was driven for 1.8 seconds, but the Tray Auxiliary Guide could not be detected by the Tray Auxiliary Guide HP Sensor (S6).
E719 Error in communication with the Copy Card Reader-F1 (serial communication)
0000 Card Reader was not connected at department management setting. Check the connection with the Card Reader.
Remove the Card Reader, and execute the following: service mode –> #CLEAR > ERR > E719.
E736 Fax Board mismatch error
0000 Combination of the Fax Board type and the country was mismatched. This error occurred in the following cases.
- Fax Board for non-Chinese models was installed to a Chinese model.
- Fax Board for Chinese models was installed to a non-Chinese model.
- For Chinese models, replace the Fax Board with that for Chinese models.
- For non-Chinese models, replace the Fax Board with that for non- Chinese models.
E804 Power Supply Cooling Fan (FM4) error
0000 A lock signal was detected for 5 seconds while the Power Supply Cooling Fan (FM4) was being stopped.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection.
Replace the Power Supply Cooling Fan (FM4).
Replace the DC Controller PCB (PCB1).
0001 A lock signal could not be detected for 5 seconds while the Power Supply Cooling Fan (FM4) was being driven.
*The same status was detected again after executing an error retry.
E805 Heat Exhaust Fan (Rear) (FM6) or (Front) (FM5) error
0000 A lock signal was detected for 5 seconds while the Heat Exhaust Fan (Rear) (FM6) was being stopped.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J212) on the DC Controller PCB (PCB1) to check the connection.
Replace the Heat Exhaust Fan (Rear) (FM6).
Replace the DC Controller PCB (PCB1).
0001 A lock signal could not be detected for 5 seconds while the Heat Exhaust Fan (Rear) (FM6) was being driven.
*The same status was detected again after executing an error retry.
0002 A lock signal was detected for 5 seconds while the Heat Exhaust Fan (Front) (FM5) was being stopped.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J212) on the DC Controller PCB (PCB1) to check the connection.
Replace the Heat Exhaust Fan (Front) (FM5).
Replace the DC Controller PCB (PCB1).
0003 A lock signal was detected for 5 seconds while the Heat Exhaust Fan (Front) (FM5) was being driven.
*The same status was detected again after executing an error retry.
E820 Developing Cooling Fan (Front) (FM7) or (Rear) (FM8) error
0000 A lock signal was detected for 5 seconds while the Developing Cooling Fan (Front) (FM7) was being driven.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection.
Replace the Developing Cooling Fan (Front) (FM7).
Replace the DC Controller PCB (PCB1).
0001 A lock signal could not be detected for 5 seconds while the Developing Cooling Fan (Front) (FM7) was being driven.
*The same status was detected again after executing an error retry.
0002 A lock signal was detected for 5 seconds while the Developing Cooling Fan (Rear) (FM8) was being stopped.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection.
Replace the Developing Cooling Fan (Rear) (FM8).
Replace the DC Controller PCB (PCB1).
0003 A lock signal was detected for 5 seconds while the Developing Cooling Fan (Rear) (FM8) was being driven.
*The same status was detected again after executing an error retry.
E822 Delivery Cooling Fan (Front) (FM3) or (Center) (FM2) or (Rear) (FM1) error
0000 A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Front) (FM3) was being driven.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J210) on the DC Controller PCB (PCB1) to check the connection.
Replace the Delivery Cooling Fan (Front) (FM3).
Replace the DC Controller PCB (PCB1).
0001 A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Front) (FM3) was being driven.
*The same status was detected again after executing an error retry.
0002 A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Center) (FM2) was being driven.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J210) on the DC Controller PCB (PCB1) to check the connection.
Replace the Delivery Cooling Fan (Center) (FM2).
Replace the DC Controller PCB (PCB1).
0003 A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Center) (FM2) was being driven.
*The same status was detected again after executing an error retry.
0004 A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Rear) (FM1) was being driven.
*The same status was detected again after executing an error retry.
Disconnect and then connect the connector (J210) on the DC Controller PCB (PCB1) to check the connection.
Replace the Delivery Cooling Fan (Rear) (FM1).
Replace the DC Controller PCB (PCB1).
0005 A lock signal was detected for 5 seconds while the Delivery Cooling Fan (Rear) (FM1) was being driven.
*The same status was detected again after executing an error retry.




Сервисные коды ошибок факса

Code Tx/Rx Description
##0100 Tx The retry count of the procedure signal has exceeded the limit at the time of transmission.
##0101 Tx/Rx The modem speed differs from that of the other party's machine.
##0102 Tx Fallback was not available at the time of transmission.
##0103 Rx EOL could not be detected for 5 seconds at the time of reception. (15sec in the case of CBT)
##0104 Tx RTN or PIN was received at the time of transmission.
##0106 Rx While waiting for a procedure signal at the time of reception, the signal could not be received for 6 seconds.
##0107 Rx Fallback was not available on the sending machine side at the time of reception.
##0109 Tx After DCS was sent at the time of transmission, a signal other than DIS, DTC, FTT, CFR, and CRP was received, and the retry count of the procedure signal exceeded the limit.
##0111 Tx/Rx Memory error
##0114 Rx RTN was sent at the time of reception.
##0200 Rx Carrier could not be detected for 5 seconds while receiving an image at the time of reception.
##0201 Tx/Rx DCN was received in a procedure other than a normal binary procedure.
##0224 Tx An error occurred in the communication procedure signal.
##0228 Rx The management information of the image was abnormal.
##0232 Tx Encode error
##0237 Rx Decode error
##0261 Tx/Rx A system error occurred.
##0280 Tx The retry count of the procedure signal has exceeded the limit at the time of transmission.
##0281 Tx
##0282 Tx
##0283 Tx
##0284 Tx DCN was received after TCF was sent at the time of transmission.
##0285 Tx DCN was received after EOP was sent at the time of transmission.
##0286 Tx DCN was received after EOM was sent at the time of transmission.
##0287 Tx DCN was received after MPS was sent at the time of transmission.
##0288 Tx After EOP was sent, a signal other than PIN, PIP, MCF, RTP, and RTN was received.
##0289 Tx
##0290 Tx
##0670 Tx At V.8 late start, the V.8 competency of DIS on the receiving machine side was detected, and a CI signal was sent. However, the procedure failed to be performed, and the circuit was released due to T1 time-out.
##0671 Rx After the CM signal of the calling party was detected at V.8 call reception, the procedure failed to move to Phase 2, and the circuit was released due to T1 timeout.
##0672 Tx At V.34 transmission, the procedure failed to move from Phase 2 to Phase 3 and later, and the circuit was released due to T1 time-out.
##0673 Rx At V.34 reception, the procedure failed to move from Phase 2 to Phase 3 and later, and the circuit was released due to T1 time-out.
##0674 Tx At V.34 transmission, the procedure failed to move from Phase 3 and 4 to the control channel and later, and the circuit was released due to T1 time-out.
##0675 Rx At V.34 reception, the procedure failed to move from Phase 3 and 4 to the control channel and later, and the circuit was released due to T1 time-out.
##0750 Tx After PPS-NULL was sent at ECM transmission, no meaningful signal was received, and the retry count of the procedure signal exceeded the limit.
##0752 Tx After PPS-NULL was sent at ECM transmission, DCN was received.
##0753 Tx After PPS-NULL was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0754 Tx After PPS-NULL was sent at ECM transmission, the retry count of the procedure signal exceeded the limit.
##0755 Tx After PPS-MPS was sent at ECM transmission, no meaningful signal was received, and the retry count of a procedure signal exceeded the limit.
##0757 Tx After PPS-MPS was sent at ECM transmission, DCN was received.
##0758 Tx After PPS-MPS was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0759 Tx After PPS-MPS was sent at ECM transmission, the retry count of the procedure signal exceeded the limit.
##0762 Tx After PPS-EOM was sent at ECM transmission, DCN was received.
##0763 Tx After PPS-MPS was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0764 Tx After PPS-EOM was sent at ECM transmission, the retry count of the procedure signal exceeded the limit.
##0765 Tx After PPS-EOP was sent at ECM transmission, no meaningful signal was received, and the retry count of the procedure signal exceeded the limit.
##0767 Tx After PPS-EOP was sent at ECM transmission, DCN was received.
##0768 Tx After PPS-EOP was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0769 Tx After PPS-EOP was sent at ECM transmission, the retry count of the procedure signal exceeded the limit.
##0770 Tx After EOR-NULL was sent at ECM transmission, no meaningful signal was received, and the retry count of the procedure signal exceeded the limit.
##0772 Tx After EOR-NULL was sent at ECM transmission, DCN was received.
##0773 Tx After EOR-NULL was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0774 Tx After EOR-NULL was sent at ECM transmission, ERR was received.
##0775 Tx After EOR-MPS was sent at ECM transmission, no meaningful signal was received, and the retry count of the procedure signal exceeded the limit.
##0778 Tx After EOR-MPS was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0779 Tx After EOR-MPS was sent at ECM transmission, ERR was received.
##0780 Tx After EOR-EOM was sent at ECM transmission, no meaningful signal was received, and the retry count of the procedure signal exceeded the limit.
##0782 Tx After EOR-EOM was sent at ECM transmission, DCN was received.
##0783 Tx After EOR-EOM was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0784 Tx After EOR-EOP was sent at ECM transmission, no meaningful signal was received, and the retry count of the procedure signal exceeded the limit.
##0787 Tx After EOR-EOP was sent at ECM transmission, DCN was received.
##0788 Tx After EOR-EOP was sent at ECM transmission, the retry count of the procedure signal exceeded the limit, or T5 time-over (60sec) occurred.
##0789 Tx After EOR-EOP was sent at ECM transmission, ERR was received.
##0790 Rx After EOR-Q was received at ECM reception, ERR was sent.
##0791 Tx A signal other than a meaningful signal was received during the ECM mode procedure.
##0792 Rx At ECM reception, PPS-NULL could not be detected between partial pages.
##0793 Rx At ECM reception, a valid frame could not be received when a high-speed signal was received, and a timeout occurred.
##0794 Tx At ECM reception, PPR with all 0 was received.
##0795 Tx/Rx A failure occurred in the decode processing during communication.

 

[×]

Có những file đã bị đặt pass, nếu muốn có pass các bạn có thể để lại 1 Comment ngay tại bài đó kèm theo mail của các bạn, nếu được duyệt sẽ có pass tại thư của bạn . Blog-HoaiTrang .!